15W Wall-mounted Charger with 0.5A Input Current, Over-current Protection and One Year Warranty

Delivery term:The date of payment from buyers deliver within days
  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2017-08-20 21:11

  • Browse the number:

    132

Send an inquiries
+
Eljintek Inc
Contactaixin:

Contactaixin:

eljintek(Ms.)  

telephone:

Area:

Beijing

Address:

6F-1, No. 286-3 Shin-Ya Road, Chien-Chen District, Kao Hsiung, Taiwan (806)

Website:

http://eljintek.bjxinlin.com/

+
Model Number: GPSU15U - X - CC (CBC) Brand Name: Eljintek Key Specifications/Special Features: Input voltages: 100 to 240V AC (limits: 90 to 264V AC) and 50 to 60Hz (limits: 47 to 63Hz)Input current: 0.5A (maximum)Output voltage: see rating chartOutput current: see rating chartOutput power range: see rating chartRipple: 1% peak to peak maximum and see rating chartOver-voltage protection: supported and provided by Zener diodeOver-current protection: supported and automatic recoveryStandard series: rated output current greater than 110% for primary-referenced direct drive Temperature coefficient: all outputs ± 0.04%/°C (maximum)Transient response: maximum excursion of 4% or better on all models recovering to 1% of final value within 500S after a 25% step load changeOperating temperatures: 0 40°CStorage temperatures: -40 to 85°CRelative humidity: 5% to 95% and non-condensingDerating: 100% at 40 to 50C at 70% Average efficiency: see rating chartSetup up, hold-up and rise time: typical, 3,000, 16 and 50m/sec at full loadLine regulation: ± 1% maximum for any input voltage change between input voltage rangeLoad regulation: typical, ± 5% variation from minimum to maximum output currentInsulation resistance: 50MΩ (minimum) from input to groundInrush current: 20A at 115V AC or 40A at 230V AC at 25°C cold startWithstanding voltage: 4,242V DC from input to outputMeantime between failure: 100,000 hours minimum at full load at 25°C ambient temperatureEMI requirements:CE emission: EN55022 and EN61000-3-2, 3Immunity: IEC61000-4-2, 3, 4, 5, 6 and 11 (B) FCC 47 CFR part 15 subpart B.ICES-003 issue 4 ANSI C63.4-2003Safety requirements:Meets UL 60950-1CSA-C22.2EN60950-1IEC60950-1 Main Export Markets: North America
  • Eastern Europe
  • Mid East/Africa
  • Central/South America
  • Asia
  • Western Europe
  • Australasia
  • Download more information about this product